MT Machine-translated from Japanese (game and mod terms use the official translations). Term sources ↓

Home › Researched mods

Vanilla Temperature Expanded

Buildings, Furniture & Decor Production, Industry & Power

Layer 1 At a glance

What the mod is, how to use it, video

Vanilla Temperature Expanded
Vanilla Temperature Expanded — Oskar Potocki, xrushha, Arquebus, Taranchuk

Central air conditioning connected by ducts, and a system that warms up with an outdoor campfire.

317.1KSubs
★4.7Workshop rating
20features
31mod images
AC control unit(ACコントロールユニット)AC compressor/Large AC compressor(ACコンプレッサー/大型)Air duct/Subterranean air duct/Air duct valve(エアダクト/地下ダクト/ダクトバルブ)Network efficiency(ネットワーク効率)Industrial heater(工業用ヒーター)Wall heater / Wall-mounted heater(壁埋め込みヒーター/壁掛けヒーター)
Basics
Type
Buildings with temperature control (central air conditioning) + Gameplay (including Proxy Heat)
Game versions
1.5, 1.6, 1.7 (1.7 reuses the 1.6 folder)
Dependencies
Harmony, Vanilla Expanded Framework (using PipeSystem). Incompatible: LongerCFloor.ProxyHeat (standalone Proxy Heat Mod)
Author
Oskar Potocki, xrushha, Arquebus, Taranchuk
License
Not specified
Workshop
3202046258 ・ 317,097 Subs ・ ★★★★★
Repository
Vanilla-Expanded/VanillaTemperatureExpanded

▼ Deeper from here

Layer 2 What is inside

Main features, category cards, tier list

Features with pictures (11)

ACControl UnitGizmo Link With ACControl UnitGizmo Unlock With ACControl UnitOverlays Overlay Missing ACControl Unit

1AC control unit

2x2. Set the target temperature for the entire network using the ±1/±10 buttons and reset (initial 21°C). An efficiency bar appears above the building (with a 3-stage color indicator). Power 200W, Steel 80, Components 6, Silver 100, Build…

ACControl UnitWall HeaterWall Mounted AC Menu IconWall Mounted Cooler Menu Icon

2AC unit/Wall-mounted AC unit

A one-unit device embedded in the wall.

VTE Ceiling Fan Large litACCompressor LargeCeiling Fan Large

3AC compressor / Large AC compressor

For outdoor use only.

Linked Vent Valve OffLinked Vent Valve

4Air duct/Subterranean air duct/Air duct valve

Pipe mesh that can be laid with 1 steel.

Gizmo Increase Network TemperatureGizmo Lower Network TemperatureGizmo Reset Network Temperature

5Network efficiency

Calculated as supply (2 per unit + compressors) minus use (1 per AC unit).

Gizmo Increase Network TemperatureGizmo Lower Network TemperatureGizmo Reset Network Temperature

6Link / Unlink temperature (Link/Unlink temperature)

Each AC unit can be excluded from the network temperature and have its temperature set individually.

Industrial CoolerIndustrial HeaterWall HeaterWall Mounted Heater Menu Icon

7Industrial heater

A 2x1 wall-mounted heater. Power 250 W. 63/s per output cell, and it pushes heat into each of its 2 cells, so 126/s per heater (6 times the vanilla heater's 21). It can heat up to 1000℃ (vanilla stops at about 1…

Industrial CoolerIndustrial HeaterStanding CoolerWall Mounted Cooler Menu Icon

8Industrial cooler

A large 2x1 cooler.

Wall Mounted AC Menu IconWall Mounted Vent Menu Icon

9Wall heater / Wall-mounted heater (built-in wall heater / wall-mounted heater)

A heater to be attached to the wall.

Linked Vent Valve OffLinked Vent ValveStanding Cooler

10Wall-mounted cooler / Wall-mounted vent

Air conditioner and vent attached to the wall.

VTE Ceiling Fan Large litVTE Ceiling Fan Small litACCompressor LargeACCompressor Small

11Small / Large ceiling fan

It can only be placed under the roof.

Show the other 9 features
12Research: "HVAC"
Added to the Vanilla Expanded tab. Prerequisites: Air Conditioning Research, Hi-Tech Research Bench, 1000pt
13Error display
"Not enough compressors", "No control unit", "2 or more control units" and "Under a roof" show up as a blinking icon with an explanation.
14Standing cooler
Desktop type. Cools only down to 14°C (freezing not possible). Consumes 13W while idle.
15Included Proxy Heat (outdoor proximity temperature)
Only a few tiles around outdoor heat and cooling sources change in temperature. Settlers will warm themselves or cool off in these areas. The range is displayed with a red/blue border when selected.
16 Automatic registration of heat sources
Automatically applies proximity temperature to all buildings, including those with HeatPusher (including mods) and temperature-controlled buildings (output is limited to ±50°C).
17 Campfire, passive cooler, and steam vent settings
Campfires have a radius of 2.5 and +18°C (max 30°C), melting surrounding snow. Passive coolers are -6°C, and steam vents are +30°C.
18AI behavior change
When hypothermia or heatstroke becomes serious, a pawn moves to a cell with a comfortable temperature (near an outdoor campfire, or somewhere cool); frostbite does not count. Cells with dangerous temperatures are also removed from where pawns wander. The temperature readout at the bottom right of the screen and the ambient temperature of things also reflect it.
19 Outdoor crop cultivation (optional)
Near a heat source, plants grow even in winter (turned ON in the settings; only on cells where the temperature with the added heat is above 0℃).
20 Gravity Ship (Odyssey) compatible
Heaters have GravshipLaunchExtension attached. Counted as heating for gravity ships (guess)

In-game photos

AC compressor
AC compressor
AC control unit
AC control unit
AC unit
AC unit
Air duct
Air duct
Industrial cooler
Industrial cooler
Industrial heater
Industrial heater
Large AC compressor
Large AC compressor
VTE_SmallCeilingFan
VTE_SmallCeilingFan
Standing cooler
Standing cooler
Air duct valve
Air duct valve
Wall heater
Wall heater
Wall-mounted cooler
Wall-mounted cooler

▼ Deeper from here

Layer 3 Numbers and caveats

Full stat tables, gaps to vanilla, husbandry, compatibility and caveats

Features not described in the introduction / Hard to understand

  • Proxy Heat: The description only mentions central air conditioning, but it actually includes a mechanism that warms only the area around outdoor campfires and heaters. There is also a settings screen where the range and temperature can be adjusted with sliders for each building. It states in About.xml that it is incompatible with the standalone Proxy Heat.
  • Removing the ceiling breaks the ceiling fan: Removing the roof causes the fan underneath to take 1000 damage and be destroyed.
  • Efficiency can exceed 100%: By oversizing the compressor, it can reach up to 150%, reducing the electricity cost of the AC unit by up to half.
  • The AC unit automatically switches between cooling and heating and produces no waste heat: Unlike a vanilla cooler, you don't have to worry about the other side of the wall.
  • Industrial heaters can be raised to 1000°C: They can be used for sauna purposes or for defense by attacking with heat (speculative use).
  • Radius has also been set for the heat sources of other VE-based mods (each generator in VQE The Generator has a radius of 10–48, the gas cooler in VHGE, and the stone campfire in VFE Medieval).
  • Brrr and Phew (Continued) Integration: The mod's evacuation behavior selects a nearby warm tile as the destination.
  • The large campfires of VFE Tribals only emit heat when the fire is lit.

Compatibility with other mods

Works with

Details
  • Incompatibility: Standalone Proxy Heat.
  • Conditional Patches: Vanilla Furniture Expanded, Vanilla Helixien Gas Expanded (Gas Cooler), Vanilla Quests Expanded - The Generator (16 types of generators).
  • The patch for Vikings is disabled in .old (in 1.6, VFE Vikings' funeral pyres and hearths are excluded).
  • Detection in C#: Brrr and Phew (Continued), VFE Tribals.
  • Extension points for other mods: ProxyHeat.ProxyHeatExtension (radius), ProxyHeat.CompProperties_TemperatureSource, TemperatureOutputPositionModExtension (position of the tile that outputs temperature).

Notes and known limitations

  • Since Thing.AmbientTemperature is being Postfixed, the ambient temperature is reflected in the temperature of all objects, such as the rate of food spoilage, outdoors (speculation: the affected area is large). This may cause a performance load on maps with many heat sources.
  • If one network has 2 or more control units, the whole network stops. Be careful not to connect too many ducts together.
  • Intermediate insertion is OK. If deleted, the building and ducts disappear (assumption, typical behavior).
  • The Japanese translation file is not included (English only).

Mod settings item (the name of the settings screen is "Vanilla Temperature Expanded")

4 options (table in layer 4).

Settings table ↓

Key operations, buttons, menus

Open (Key operation, button, menu)
  • AC Control Unit: Buttons for -10 / -1 / Reset / +1 / +10 (Hotkeys Misc1-5). Pressing them displays the set temperature on all linked AC units.
  • AC Unit: Link/Unlink temperature (Misc3). The vanilla temperature button appears only when unlinked.
  • Duct valve: Open/close button (settlers go to operate it).
  • A button to dismantle ducts is added to the 'Temperature' category of the Building menu.

▼ Deeper from here

Layer 4 For the deep divers: how it works in the source

Mechanisms read from source, raw Defs values, formulas, open questions

From here on: site-only detail (not covered in the video)

Mod settings item (the name of the settings screen is "Vanilla Temperature Expanded")

Open the table (4 rows)
Setting (as shown)DefaultEffect
Enable proxy heat(Enable proxy heat)ONTurn the entire outdoor proximity temperature system ON/OFF
Enable proxy heat effect indoorsOFFApply proximity temperature to indoor tiles as well
Allow plant growth inside proxy heat effect radiusOFFNear a heat source, crops grow even in cold seasons (only on cells where the temperature with the added heat is above 0℃ and below 58℃; HarmonyPatches.cs:494-500).
Proxy heat building settings (settings per building)Auto-generatedModify the Enabled, Proxy heat radius (radius 1.5–10), Minimum/Maximum temperature threshold (minimum/maximum temperature. Unset is also possible), and Temperature output (output temperature) for each building. There is a Search field and a Reset button.

Features and evidence (files, classes)

Open the table with evidence (20 rows)
#FeatureIn-game appearance / controlsEvidence (file/class)
1Research "HVAC"Added to the Vanilla Expanded tab. Prerequisites: Air Conditioning Research, Hi-Tech Research Bench, 1000ptResearchProjects_Various.xml (VTE_HVAC)
2AC control unit2x2. Set the target temperature for the entire network using the ±1/±10 buttons and reset (initial 21°C). An efficiency bar appears above the building (with a 3-stage color indicator). Power 200W, Steel 80, Components 6, Silver 100, Construction 8Building_AcControlUnit、CompResourceSingleton
3AC unit / Wall-mounted AC unitA 1-tile device embedded in the wall. Automatically switches between cooling and heating (no heat exhaust side) according to the room temperature. Maximum temperature 120°C. Power 100WBuilding_AcUnit、CompAcTempControl
4AC compressor / Large AC compressorFor outdoor use only. Stops when under a roof. Provides +2/+6 efficiency (large is 2x2)CompResourceTrader_Compressor
5Air duct / Subterranean air duct / Air duct valvePipe net that can be laid with Steel 1. Flow can be opened and closed with a valve (colonists must go to operate it). Has a duct net-specific overlay display. When damaged, it produces dirt.ACNet.xml (PipeNetDef VTE_EfficiencyNet, CompProperties_SpillWhenDamaged)
6Network efficiencyCalculated as supply (2 per unit + compressors) minus use (1 per AC unit). Each 1 of shortage gives −5%, each 1 of surplus gives +1%, up to 150%. Power use is "base × (2 − efficiency)", so a surplus lowers the power bill (half at 150%). If efficiency reaches 0%, the whole network stops.AcPipeNet.CalculateEfficiency、Building_AcUnit.TickRare
7Error display"Not enough compressors", "No control unit", "2 or more control units" and "Under a roof" show up as a blinking icon with an explanation.CompResourceTrader_AC / _Compressor(Overlay_*)
8Link / Unlink temperatureEach AC unit can be excluded from the network temperature and have its temperature set individually.CompAcTempControl.IndependentTemp
9Industrial heaterA 2x1 wall-mounted heater. Power 250 W. 63/s per output cell, and it pushes heat into each of its 2 cells, so 126/s per heater (6 times the vanilla heater's 21). It can heat up to 1000℃ (vanilla levels off at around 120℃). Research: electricity only.Building_TwoCellHeater (maxTemperature 1000)
10Industrial coolerA large 2x1 cooler. One side blows cold air, the other side vents heat. −63/s per output cell, and it works on each of its 2 pairs, so −126/s per cooler (6 times the vanilla cooler's −21). Power 300 W. Made for freezers.Building_TwoCellCooler
11Wall heater / Wall-mounted heater (built-in wall heater / wall-mounted heater)A heater that attaches to the wall. 175W, 21/second. A tile that emits warm air is displayed during installation.Building_HeaterWithOffset、PlaceWorker_HeaterWithOffset
12Wall-mounted cooler / Wall-mounted ventAir conditioners mounted on the wall and ventilation openings. The ventilation openings equalize the temperature without allowing people to pass through.VEF CompProperties_MountableOnWall
13Standing coolerDesktop type. Cools only down to 14°C (freezing not possible). Consumes 13W while idle.CompHeatPusherPoweredWithIdleDraw
14Small / Large ceiling fanIt can only be placed under a roof. It cannot be placed side by side. It cools down to 17°C. The fan rotation speed changes during operation. Small: 30W (standby 3W), Large: 50W (standby 5W)Building_CeilingFan、CompCeilingFan、PlaceWorker_UnderRoof / NeverAdjacentCeilingFan
15Included Proxy Heat (outdoor proximity temperature)Only a few tiles around outdoor heat and cooling sources change in temperature. Settlers will warm themselves or cool off in these areas. The range is displayed with a red/blue border when selected.Source/ProxyHeat(ProxyHeat.dll)、CompTemperatureSource
16Automatic registration of heat sourcesAutomatically applies proximity temperature to all buildings, including those with HeatPusher (including mods) and temperature-controlled buildings (output is limited to ±50°C).Startup.AutogenerateProxyHeatComps
17Setting up campfires, passive coolers, and steam ventsCampfires have a radius of 2.5 and +18°C (max 30°C), melting surrounding snow. Passive coolers are -6°C, and steam vents are +30°C.Patches/Vanilla_Patches.xml
18Change in AI behaviorWhen hypothermia or heatstroke becomes serious, a pawn moves to a cell with a comfortable temperature (near an outdoor campfire, or somewhere cool); frostbite does not count. Cells with dangerous temperatures are also removed from where pawns wander. The temperature readout at the bottom right of the screen and the ambient temperature of things also reflect it.HarmonyPatches (JobGiver_SeekSafeTemperature, RCellFinder.CanWanderToCell, GlobalControls.TemperatureString, Thing.AmbientTemperature)
19Outdoor crop cultivation (optional)Near a heat source, plants grow even in winter (turned ON in the settings; only on cells where the temperature with the added heat is above 0℃).Patch_GrowthSeasonNow / GrowthRateFactor_Temperature
20Compatible with Gravity Ship (Odyssey)Heaters have GravshipLaunchExtension (isHeater). Counted as heating for gravity ships (guess).Buildings_Temperature.xml

Unverified or inferred statements

Open 4
  • 20 — Gravity Ship (Odyssey) compatible ...
  • Industrial heaters can be raised to 1000°C: They can be used for sauna purposes or for defense by attacking with heat (speculative use).
  • Since Thing.AmbientTemperature is being Postfixed, the ambient temperature is reflected in the temperature of all objects, such as the rate of food spoilage, outdoors (speculation: the affected area is large). This may cause a performance load on maps with many heat sources.
  • Intermediate insertion is OK. If deleted, the building and ducts disappear (assumption, typical behavior).

Commit read

https://github.com/Vanilla-Expanded/VanillaTemperatureExpanded
eabd366077064a341ec50701de3ffe4cc504f263

Credit

Vanilla Temperature Expanded — Oskar Potocki, xrushha, Arquebus, Taranchuk ・ Steam Workshop ・ GitHub

Image and license notes (from the report)